Skip to content
Snippets Groups Projects
  1. Jan 13, 2017
    • Jure Bericic's avatar
      Added new leafs with all flash250 ADC data to tree. · b3310051
      Jure Bericic authored
       - Added new leafs to the hodoscope tree.
       - Added new leafs to the aerogel tree.
       - Added new leafs to cerenkov tree.
       - Added new leafs to the shower tree.
      
      Left all the old leafs in there. Will need a careful cleanup...
      b3310051
  2. Dec 17, 2016
    • Jure Bericic's avatar
      Added new methods to THcRawAdcHit. · 27a18730
      Jure Bericic authored
      27a18730
    • Jure Bericic's avatar
      Added THcRawAdcHit and included it in THcRawShowerHit. · 6e184a5a
      Jure Bericic authored
      The new class THcRawAdcHit is meant to represent the raw ADC hits. The
      logic with dealing with ADCs has become quite complex now and it would
      have to be multiplicated across all detectors that have ADC
      channels. While this by itself is not such a big problem, fixing
      possible bugs in multiple places is.
      
      I also redesigned the THcRawShowerHit class to use the new
      THcRawAdcHit. The redesign was due anyway, so I took the opportunity.
      
      I also had to modify THcShowerArray and THcShowerPlane. They still
      need some work to use the the new flash 250 data, but changes were
      necessary anyway.
      
      Minor fix 01.
      6e184a5a
  3. Dec 15, 2016
  4. Oct 17, 2016
  5. May 18, 2016
  6. Jan 22, 2016
  7. Jan 19, 2016
  8. Jan 15, 2016
  9. Jan 10, 2016
  10. Jan 09, 2016
  11. Jan 01, 2016
  12. Dec 29, 2015
  13. Dec 17, 2015
  14. Dec 16, 2015
  15. Dec 11, 2015
  16. Dec 06, 2015
  17. Nov 04, 2015
  18. Oct 14, 2015
    • Stephen A. Wood's avatar
      FADC compatibility for raw shower hits · af6fa628
      Stephen A. Wood authored
        A shower counter hit can now be multiple samples, with a different
        number of samples allowed for positive and negative tubes.
        GetData(signal) now returns the sum of all the samples.  This should
        still be compatible with fastbus ADCs as they are a single sample
        (which is already the integral.)
      af6fa628
    • Stephen A. Wood's avatar
      Very basic support for the SHMS shower counter · 1e6b0020
      Stephen A. Wood authored
        Added as an optional sub detector THcShowerArray to the THcShower class
        Get hit data with GetData method instead of hit member variables
          so as to be compatible with FADC compatible hit list
      1e6b0020
Loading