    Mark Jones authored
    Dave Mack introduced two new variables to the
    calculation of beam current to described correction for
    the nonlinearity above 60uA in BCM1 and BCM2
    seen in the Fall 18, Spring 19 and Summer 19running.
    See for example summer 2019
    hallcweb.jlab.org/doc-private/ShowDocument?docid=1037
    Fall 18/Spring 19
    hallcweb.jlab.org/doc-private/ShowDocument?docid=1042
    
    For a BCM scaler read the difference, Dcounts, from the
    previous scaler and get the time difference, Dtime.
    Original calculation is:
    I = (Dcounts/Dtime-fBCMOffset)/BCM_Gain
    Now add an non-linearity correction
    I = I + fBCM_SatQuadratic*Max(I-fBCM_SatOffset,0.0)^2
    
    Add parameters fBCM_SatOffset and fBCM_SatQuadratic
    that can be optional read-in. If parameters are
    not read-in the parameters are set to zero, so
    there is no correction.
    
    Add the non-linearity correction to all BCM current
    calculations.
    e5b40a34
    History
    Updated THcScalerEvtHandler
    Mark Jones authored
    Dave Mack introduced two new variables to the
    calculation of beam current to described correction for
    the nonlinearity above 60uA in BCM1 and BCM2
    seen in the Fall 18, Spring 19 and Summer 19running.
    See for example summer 2019
    hallcweb.jlab.org/doc-private/ShowDocument?docid=1037
    Fall 18/Spring 19
    hallcweb.jlab.org/doc-private/ShowDocument?docid=1042
    
    For a BCM scaler read the difference, Dcounts, from the
    previous scaler and get the time difference, Dtime.
    Original calculation is:
    I = (Dcounts/Dtime-fBCMOffset)/BCM_Gain
    Now add an non-linearity correction
    I = I + fBCM_SatQuadratic*Max(I-fBCM_SatOffset,0.0)^2
    
    Add parameters fBCM_SatOffset and fBCM_SatQuadratic
    that can be optional read-in. If parameters are
    not read-in the parameters are set to zero, so
    there is no correction.
    
    Add the non-linearity correction to all BCM current
    calculations.