; Add ability to write out the scaler rate at each scaler read
; for up to 10 scalers
; When g_writeout_scaler_filename is commented out then file
; is not written and other info not used.
; To get scaler indices look in TEMPLATE/hreport.template
; and sreport.template .
; In output file for each scaler read is the number of the scaler read and the
; time between scaler reads and then the rates for each scaler.
g_writeout_scaler_filename = outfiles/%d.scal
INDEX_WRITEOUT_SCALERS = 146,165,148,164,160,174
NUM_WRITEOUT_SCALERS = 6
; Old charge calibrations from Run 16707; BCM1 in gain pos 1, BCM2 in
; gain position 2
;point to scaler indices for BCM's fro SOS scalers
; gbcm1_index = 321
; gbcm2_index = 322
; gbcm3_index = 323
; gunser_index = 324
;point to scaler indices for BCM's for HMS scalers
gbcm1_index = 167
gbcm2_index = 168
gbcm3_index = 323
gunser_index = 166
;gain factors for three cavity monitors
; numbers from I. Albayrak - 5/11/07
gbcm1_gain = 0.000334137 ; microA/Hz
gbcm2_gain = 0.000373754 ; microA/Hz
gbcm3_gain = 0.00043343 ; microA/Hz
gunser_gain = 0.00024980 ; microA/Hz
; note, gbcm3_gain from:
; JRA - adjust calibration factors by hand
; to get semi-sensible values (apr03)
; numbers from I. Albayrak - 5/11/07
gbcm1_offset = 251226. ; Hz
gbcm2_offset = 250816. ; Hz
gbcm3_offset = 245437. ; Hz
gunser_offset = 250000. ; TEST
; gbcm3_offset and gunser_offset from:
; VALUES FROM BEAM OFF (starting point for jan99)
;define the threshold current at which beam is "on". (in microamps)
g_beam_on_thresh_cur = 5.,5.
bcm_for_threshold_cut = 1
;point to hardware clock (1MHz scaler, scaler channel 174 in HMS scalers)
; for SOS scalers 325
; gclock_index = 174
gclock_index = 325
gclock_rate = 1.e+6
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
; everything below this line is old js 6.22.4
;gain factors for three cavity monitors
; gbcm1_gain = .0009435 ; microA/Hz
; gbcm2_gain = .0002849 ; microA/Hz
; gbcm3_gain = .0002537 ; microA/Hz
; gunser_gain = .00025000 ; microA/Hz
;
; From Feb99 BCM cal:
; gbcm1_gain = .00004811 ; microA/Hz
; gbcm2_gain = .00026421 ; microA/Hz
; gbcm3_gain = .00043343 ; microA/Hz
; gunser_gain = .00025000 ; microA/Hz
; JRA - adjust calibration factors by hand to get semi-sensible values (apr03)
; gbcm1_gain = .00008685 ; microA/Hz
; gbcm2_gain = .00029148 ; microA/Hz
; gbcm3_gain = .00043343 ; microA/Hz
; gunser_gain = .0002501 ; microA/Hz
; BCM1 and BCM2 values updated to match what Gaskell put into the
; ratemon code [based on hclog 70221, Dec 8, 2003]
;gbcm1_gain = 0.001101
;gbcm2_gain = 0.0012963
;zero offsets for BCM s
; VALUES FROM REAL FIT:
; gbcm1_offset = 250632. ; Hz
; gbcm2_offset = 251195. ; Hz
; gbcm3_offset = 249543. ; Hz
;
; VALUES FROM BEAM OFF (starting point for jan99)
; gbcm1_offset = 244795. ; Hz
; gbcm2_offset = 253647. ; Hz
; gbcm3_offset = 245437. ; Hz
; gunser_offset = 250000. ; TEST
; gunser_offset = 545693. ; Hz
; BCM1 and BCM2 values updated to match what Gaskell put into the
; ratemon code [based on hclog 70221, Dec 8, 2003]
;gbcm1_offset = 250513
;gbcm2_offset = 250463