Skip to content
Snippets Groups Projects
Commit 7fc8a6ea authored by hallc-online's avatar hallc-online
Browse files

Update PARAM files for hodo calibration

Create two files
htofcalib.param
ptofcalib.param

Each of these files sets the flag to dump the tof calibration
data to a file that is designated in the file.
The user has to add a line
gHcParms->Load("PARAM/HMS/HODO/htofcal.param");

or

gHcParms->Load("PARAM/SHMS/HODO/ptofcal.param");
to the replay script to get the  data files hodo calibration

Remove these parameters from the regular hodo calibration files.
parent c1277892
No related branches found
No related tags found
No related merge requests found
......@@ -19,10 +19,10 @@ Compiling code
Running code
-----------
* First replay data with either
** HMS: gHcParms->Load("PARAM/HMS/HODO/htofcal.param");
** SHMS: gHcParms->Load("PARAM/HMS/HODO/ptofcal.param");
* The replay should put the new file : hfort.37 or pfort.37 in the CALIBRATION/hodo_calib directory
* First replay data by adding either line to replay script
** HMS: gHcParms->Load("PARAM/HMS/HODO/CALIB/htofcal.param");
** SHMS: gHcParms->Load("PARAM/SHMS/HODO/CALIB/ptofcal.param");
* The replay will put the new file : hfort.37 or pfort.37 in the CALIBRATION/hodo_calib directory
* Copy either hmstofcal.inp or shmstofcal.inp to tofcal.inp
* Execute ./tofcal
* Print out info on the initial chi2 of data and final chi2 of the fit.
......
;HMS Hodo Calibration paramters
hdumptof=1
hdumptof_filename="CALIBRATION/hodo_calib/hfort.37"
; new param from KPP HMS run 303
hhodo_pos_invadc_offset = -0.00, -0.00, -0.70, -0.00
......
;HMS Hodo Calibration paramters
hdumptof=1
hdumptof_filename="CALIBRATION/hodo_calib/hfort.37"
hhodo_pos_invadc_offset = 0.000, 0.0000, 0.000, 0.000
0.000, 0.0000, 0.000, 0.000
0.000, 0.0000, 0.000, 0.000
......
; set hdumptof =1 to write out the calibration file
hdumptof=1
hdumptof_filename="CALIBRATION/hodo_calib/hfort.37"
pdumptof = 1
pdumptof_filename = "CALIBRATION/hodo_calib/pfort.37"
phodo_pos_invadc_offset = -5.0000, -5.0000, 0.000, 0.000
-5.0000, -2.0000, 0.000, 0.000
......
; set pdumptof =1 to write out the calibration file
pdumptof = 0
pdumptof_filename = "CALIBRATION/hodo_calib/pfort.37"