Skip to content
Snippets Groups Projects

Resolve "50cm shift of lattice and FF detectors"

Merged Alex Jentsch requested to merge 35-50cm-shift-of-lattice-and-ff-detectors into master
Compare and Show latest version
7 files
+ 22
19
Compare changes
  • Side-by-side
  • Inline
Files
7
+ 3
3
@@ -5,14 +5,14 @@
### B0 Tracker Parameters
</comment>
<constant name="B0Preshower_rotation" value="ionCrossingAngle"/>
<constant name="B0Preshower_Station_1_xpos" value="-0.15749922*m" />
<constant name="B0Preshower_Station_1_xpos" value="-0.17249922*m" />
<constant name="B0Preshower_length" value="5.0*cm" />
<comment>
where do these numbers come from?
</comment>
<constant name="B0PreshowerCenter_xpos" value="-0.15749922*m" />
<constant name="B0PreshowerCenter_zpos" value="6.2*m" />
<constant name="B0PreshowerCenter_xpos" value="-0.17249922*m" />
<constant name="B0PreshowerCenter_zpos" value="6.7*m" />
<comment>
This angle is the angle subtended in phi for each trap segment.
Loading